ISO 9000
PRESSURE TRANSDUCERS
Keeping pressure under control
Pressure Transducers
Expertise in pressure sensing technology enables us to manufacture to the highest standard of quality and reliability.
Our quality management system, which is
approved by B. S. I. Quality assurance to BS EN 9001,
ensures that all products have been correctly assembled
and tested prior to despatch to our customers.
Bailey & Mackey aims to lead its chosen
sectors of the Pressure Gauge, Temperature
Gauge, Pressure Switch and Pressure
Transducer Industry through excellence in
customer service and product quality.
Bailey & Mackey – Pressure control experience and
innovation for over 75 years
Pressure Transducers Pressure Transducers
Contents
Type Description Page
481 Piezo-Resistive Transducers 2
0–10V & 4–20 mA output devices
Mono Pressures from vacuum to 20 bar
482 Piezo-Resistive d.p. Transducers 4
0–10V & 4–20mA output devices
Differential Pressures from vacuum to 10 bar
2200 Piezo-Resistive Transducers 6
& 2600 0–10V & 4–20 mA output devices
Mono Pressures from vacuum to 200 bar
Gauge & Absolute
Diaphragm seal, High temperature
and Flange mounted versions 11
4000 Hall Effect Transducers 12
0–10V & 4–20 mA output devices
Mono Pressures from vacuum to 25 bar
4000 Hall Effect d.p. Transducers 14
0–10V & 4–20 mA output devices
Differential Pressures from vacuum to 25 bar
4101 Potentiometric Transducers 16
Voltage output device Mono Pressures
from 25 bar to 700 bar
73PT Potentiometric Transducers 17
Voltage & current output devices
Mono Pressures from vacuum to 600 bar
Bailey & Mackey pressure transducers
are divided into two groups each being based on a
different measuring technology.
The first group are:
Piezo-Resistive Transducers which use the
voltage that is generated when a semi-conductor
beam is deflected by an applied pressure, this
voltage is then amplified which in turn gives a voltage
or milli-amp output.
These devices give greater accuracies than the
Hall Effect devices and we manufacture this type of
transducer from ±0.1% to ±0.5% depending on the
application.
The second group are:
Hall Effect Transducers which uses a magnet
and a flux strength device to measure the deflection
of a diaphragm under pressure and give an analogue
signal to an amplifier which in turn gives a voltage or
milli-amp output.
These devices are low cost and have a similar
accuracy to a pressure gauge.
Both types of transducer outlined above have CE
marked versions to EN 50081 & EN 50082 for EMC
emission and immunity.
Corrosion resistant materials are available for both
70PT
the Hall Effect and the Piezo-resistive types to enable
them to be used on most fluids.
Bailey & Mackey Transducers can be
modified to make them more suitable for the 69PT
application on which they are to be used, please
contact our sales office for further assistance.
No maintenance is required with the pressure
transducers in this catalogue but periodic calibration
checks should be made and any re-calibration
adjustments made to ensure optimum performance.
A range of instruments calibrated to correspond with
the pressure transducers are also illustrated in this
catalogue.
Potentiometric Transducers
Voltage & current output devices
Mono Pressures from 2.5 bar to 40 bar
18
Potentiometric d.p.Transducers
Voltage & current output devices
Differential Pressures from 2.5 bar to 6 bar
19
Displays & Power Supplies 20
Chemical Compatibilities 24
Installation Instructions &
Conversion Factors 25
1
Series 400 Pressure Transducers Series 400 Pressure Transducers
This series of miniature pressure
transducers have a piezo-resistive
sensor and a unique conductive seal
that eliminates internal wire bonding
thus enhancing reliability. Zero and full
scale adjusters are provided under the
top cover. They are ideal for use in areas
requiring exact pressure measurement. low
hysteresis and long term stability. For all
applications where air. oil or water is to
be monitored.
Features
5
Piezo-resistive sensor
5
Ranges from full vacuum to 20 bar
5
Type 481A for 12/24V d.c. input,
4-20mA output
5
Type 481B for 24V a.c/d.c. input,
0-10V d.c. output
5
Supplied with 1 M flying lead
5
Pressure connection 1/4” bsp
parallel male brass
5
CE marked to EN 61000-6-2
5
Complete with mounting bracket
5
Enclosure rating IP65
5
Weight 350 grams
Mechanical Electrical
Specifications
Pressures
Pressure Ranges
0 to 35 mbar
0 to 70 mbar
0 to 350 mbar
0 to 1 bar
0 to 2 bar
0 to 7 bar
0 to 17 bar
Intermediate ranges to suit application.
Proof Pressure
1.5 x FS
Performance
Accuracy 0.25% FS
Repeatability 0.2% FS/Year typical
Thermal Error 0.026% FS/°C from
20°C
Temperature Range -20 to +80°C
Mechanical Configurations
Pressure Connection 1/4” bsp male brass
Wetted Parts
Compatible with air,
water and oil.
Type 481A
Input 12 to 24V d.c.
Output 4 to 20mA (2 wire)
Type 481B
Input 24V a.c./d.c.
Output 0 to 10V d.c. (3 wire)
These transducers must be adequately
earthed to meet EN 61000-6-2.
2
Pressure Transducers Series 400
DIMENSIONS
Pressure Transducers Series 400
DIMENSIONS
30
19
(12.7)
(23.7)
G1/4
24
11.0
WALL
FIXING
Ø40.0
Ø44.5
(22.0)
(32.0)
4.0
2 x Ø4.20
14.0 A/F
(TYP.)
14.0
BRACKET
TYPICAL WIRING DIAGRAMS
Electrical Connections
Type 481A: mA Output
Red +ve 12 – 24V d.c.
WHITE OUTPUT 4 – 20mA
DRAIN (EARTH)
Type 481B: Voltage Output
RED 24V a.c./d.c.
WHITE OUTPUT 0 – 10V
BLACK – COMMON
DRAIN (EARTH)
3
Series 400 Pressure Transducers Series 400 Pressure Transducers
This series of miniature differential
pressure transducers have a piezoresistive
sensor and a unique conductive
seal that eliminates internal wire bonding
thus enhancing reliability. Zero and full
scale adjusters are provided under the
top cover. They are ideal for use in areas
requiring exact pressure measurement, low
hysteresis and long term stability. For all
applications where air. oil or water is to
be monitored.
Features
5
Piezo-resistive sensor
5
Ranges from full vacuum to 20 bar
5
Type 482A for 12/24V d.c. input,
4-20mA output
5
Type 482B for 24V a.c/d.c. input,
0-10V d.c. output
5
Supplied with 1 M flying lead
5
Pressure connection 1/8” bsp
parallel female brass
5
CE marked to EN 61000-6-2
5
Complete with mounting bracket
5
Enclosure rating IP65
5
Weight 350 grams
Mechanical
Specifications
Electrical
Specifications
Pressures
Pressure Ranges
0 to 35 mbar
0 to 70 mbar
0 to 350 mbar
0 to 1 bar
0 to 2 bar
0 to 7 bar
0 to 17 bar
Intermediate ranges to suit application.
Proof Pressure
1.5 x FS
Out of Balance
Pressure 1.5 x FS
Line Pressure
34 bar G
Performance
Accuracy 0.25% FS
Repeatability 0.2% FS/Year typical
Thermal Error 0.026% FS/°C from
20°C
Temperature Range -20 to +80°C
Mechanical Configurations
Pressure Ports 1/8” bsp female
brass
Wetted Parts Compatible with air,
water and oil.
Type 482A
Input 12 to 24V d.c.
Output 4 to 20mA (2 wire)
Type 482B
Input 24V a.c./d.c.
Output 0 to 10V d.c. (3 wire)
These transducers must be adequately
earthed to meet EN 61000-6-2.
4
DIMENSIONS
Pressure Transducers Series 400
DIMENSIONS
Pressure Transducers Series 400
Ø40.0
Ø44.5
30
19
(12.7)
(23.7)
12.0
WALL
FIXING
BRACKET
14.0
G1/8
(22.0)
(32.0)
4.0
2 x Ø4.20
14.0 A/F
(TYP.)
TYPICAL WIRING DIAGRAMS
Electrical Connections
Type 482A: mA Output
Red +ve 12 – 24V d.c.
WHITE OUTPUT 4 – 20mA
DRAIN (EARTH)
Type 482B: Voltage Output
RED 24V a.c./d.c.
WHITE OUTPUT 0 – 10V
BLACK – COMMON
DRAIN (EARTH)
5
Series 2200 & 2600 Pressure Transducers Series 2200 & 2600 Pressure Transducers
The 2200 series features stability and
accuracy in a variety of enclosure options.
The 2600 series extends the packaging
options via an all welded stainless steel
back end for demanding submersible and
industrial applications.
The 2200 and the 2600 feature proven CVD
sensing technology, an ASIC (amplified
units) and modular packaging to provide a
sensor line that fits most applications and
can easily accommodate specials whilst
not sacrificing high performance.
Mechanical
Specifications
Features
5
Gauge, absolutem vacuum and
compound pressure models
available
5
Submersible, general purpose and
wash down enclosures
5
High stability achieved by CVD
sensing element
5
Millivolt, voltage and current output
models
5
Ranges from vacuum to 400 barG,
0 to 25 barA
5
CE marked to EN 61000-6-2 and
UL approved
Electrical
Specifications
Pressures
Pressure Ranges
Vacuum to 400 bar
Gauge and 0 to 25
bar Absolute
Intermediate ranges to suit application.
Proof Pressure
2 x FS (1.5 x FS for
400 barG)
Performance
Accuracy 0.25% FS typical
(optional 1.5% FS)
Thermal Error 1.5% FS typical
(optional 1% FS)
Temperature Range -20 to +80°C
Long Term Drift 0.2% FS/year
Mechanical Configurations
Wetted Parts 17-7 PH
Stainless Steel
Pressure
Connection
See ordering
chart
Enclosure 316 ss, 17/7 ph ss
Vibration 35g peak sinusoidal,
5 to 2KHz
Acceleration 100g steady acceleration
in any direction 0.032%
FS/g for 1 bar range
decreasing logarithmically
to 0.0007% FS/g for 400
bar range
Weight Approx 100g (additional
cable 75g/m)
Millivolt Output Units
Output 100mV ±1mV
Supply Voltage 10 Vdc (15 Vdc max)
regulated
Bridge Resistance 4 to 20mA (2 wire)
Voltage Output Units
Output See ordering chart
Supply 1.5V above FS output
to 35 Vdc at 6mA
Min Load Resistance FS output/2K ohms
Current Approx 6mA at 7.5V
Consumption output
Current Output Units
Output 4–20mA (2 wire)
Supply Voltage (VS) 7 to 35 Vdc. Above
100°C supply limited
to 24 Vdc
Supply Sensitivity 0.01% FS/Volt
Max Loop Resistance (VS-7) x 50 ohms
6
Pressure Transducers Series 2200 & 2600 Pressure Transducers Series 2200 & 2600
How to Order
Use the bold characters from the chart below to construct a product code
2200B GA6001 A 3 U A
Series
2200 2600
Output
A – 100mV
B – 4–20mA
C – 1–6V
D – 1–11V
H – 1–5V
J – 0.5–5.5V
R – 0–5V
S – 0-10V
Pressure Datumn
A* – Absolute G – Gauge
*Max absolute range is 25 bar.
Pressure Range – bar (see note 3)
A10 – 0–1 B25 – 0–25 Vac = -1 bar
A16 – 0–1.6 B40 – 0–40 1A0 – Vac–0
A25 – 0–2.5 B60 – 0–60 1A6 – Vac–0.6
A40 – 0–4 C10 – 0–100 2A5 – Vac–1.5
A60 – 0–6 C16 – 0–160 4A0 – Vac–3
B10 – 0–10 C25 – 0–250 6A0 – Vac–5
B16 – 0–16 C40 – 0–400 1B0 – Vac–9
1B6 – Vac–15
2B5 – Vac–24
4B0 – Vac–39
Pressure Range – psi (see note 3)
Performance Code
A – .25%/1.5%
B – .15%/1.0%
Cable Length
See Table 1
Apparatus Protection
2 – mV Transient Protection CE Mark
3 – Amplified RFI Protected CE Mark
Electrical Connection
2200 Series
A – Industrial DIN Mating Connector
Supplied
B – Industrial DIN Mating Connector
Not Supplied
2 – Cable Nema 4 USA
0 – Cable Weatherproof IP65 Europe
F – Cable Gland Metal lP67
2600 Series
C – Fixed Plug Size 10–6 Mating
Plug Not Supplied
G – Fixed Plug To DIN 43650
Mating Plug Supplied
M – Moulded Cable Immersible Max.
(See Note 1)
1 – Fixed Plug Size 8–4 Mating
Plug Not Supplied
F15 – 0–15 G60 – 0–600
F30 – 0–30 H10 – 0–1,000
F60 – 0–60 H15 – 0–1,500
G10 – 0–100 H20 – 0–2,000
G15 – 0–150 H30 – 0–3,000
G20 – 0–200 H40 – 0–4,000
G30 – 0–300 H50 – 0–5,000
G50 – 0–500 H60 – 0–6,000
Pressure Port
Vac = -15 psi
1F5 – Vac–0
3F0 – Vac–15
6F0 – Vac–45
1G0 – Vac–85
1G5 – Vac–135
3G0 – Vac–185
3G0 – Vac–285
01 – G1/4 External 08 – 1/8-27 NPT External
02 – 1/4-18 NPT External 09 – G1/8 Internal
03 – G1/2 Manometer 00 – G1/4 Internal
04 – 7/16-20UNF to SAE J514 OA – R1 /4 External
05 – G1/4 Ext. Soft Seal 19 – Nose Cone (2600 Only) 3 – Conduit Connector 1/2NPT
Others – Consult Factory Ext. 1M Cable (See Note 2)
7
Series 2200 & 2600 Pressure Transducers Series 2200 & 2600 Pressure Transducers
Dimensions – 2200 Series
G 1/4 Internal
Industrial DIN Connector
IP65 or NEMA4 Cable
Maximum diameter
27.4mm (1.07”)
Code ‘D’ or ‘2’
Code ‘B’
Industrial DIN Connector
(Mate Supplied)
mV Gauge/Absolute
Amplified Gauge
Code ‘A’
IP67 Cable
Amplified Absolute
Code ‘F’
Code
‘00’
G 1/4 External
1/4–1/8 NPT
G 1/2 Manometer
7/16–20 UNF–2A
G 1/4 Soft Seal
Code
‘01’
Code
‘02’
Code
‘03’
Code
‘04’
Code
‘05’
1/8–27 NPT
R 1/4
G 1/8 Internal
Code
‘08’
Code
‘0A’
Code
‘09’
8
Pressure Transducers Series 2200 & 2600 Pressure Transducers Series 2200 & 2600
Dimensions – 2600 Series
G 1/4 Internal
10–6 or 8–4 Mil–C Connector
Large DIN 43650 Plug
(Mate Supplied)
Conduit Connector with Cable
Conduit Connector
with Flying Leads
mV Gauge/Absolute
Amplified Gauge
Amplified Absolute
Maximum diameter
27.4mm (1.07”)
R 1/4
G 1/8 Internal
Code
‘19’
Code ‘29’
Moulded, Immersible Cable
Code
‘00’
G 1/4 External
1/4–1/8 NPT
G 1/2 Manometer
7/16–20 UNF–2A
G 1/4 Soft Seal
Code
‘01’
Code
‘02’
Code
‘03’
Code
‘04’
Code
‘05’
1/8–27 NPT
R 1/4
G 1/8 Internal
Code
‘08’
Code
‘0A’
Code
‘09’
Series 2200 & 2600 Pressure Transducers Series 2200 & 2600 Pressure Transducers
Electrical Connections
Connection Code mV Units Current units (4-20mA) Voltage units
IN+ OUT+ OUT-IN(+)
(-) EARTH IN+ COM OUT+ EARTH
A, B, G Industrial DIN PIN 1 2 3 E 1 2 4 1 2 3 4
C "10-6 Bayonet" PIN A B C D A B E A C B E
D "cable" R Y BL G R BK DRAIN R BK W DRAIN
F "IP 67 cable" R Y BL G R BL DRAIN R BK W DRAIN
M "Immersible R Y BL W R BL DRAIN R W Y DRAIN
1 "8-4 Bayonet" PIN A B C D A B D A C B D
2 "cable" R W G BK R BK DRAIN R BK W DRAIN
3 "conduit & cable" R W G BK R BK DRAIN R BK W DRAIN
Cable Legend: R = Red; BL = Blue; BK = Black; W = White; G = Green; Y = Yellow
Notes
1. Where electrical connection -M is specified, customer must select cable length from Table 1.
2. Where electrical connection -3 and cable length -U occur in part number, the unit will be supplied with flying leads (IP30).
3. Additional Pressure Ranges are available. Minimum range 500mb – please consult factory.
Table 1 – Cable Units
(2600 Series) (2200 Series select ‘U through ‘G’)
Code Length (M)
U No Cable Fitted
D 1
E 3
Code Length (M)
F 5
G 10
H 15
J 20
Code Length (M)
K 25
L 30
M 40
N 50
Code Length (M)
p 75
Q 100
R 125
S 150
Code Length (M)
4 170
5 200
6 225
Pressure Transducers Series 2200 & 2600 Pressure Transducers Series 2200 & 2600
Options and Variations for Series 2200 & 2600
TYPE 453 L Chemical seal version
This option is intended for harsh fluids as Accuracy
it can be fitted with corrosion resistant
wetted parts. linearity ± 0.75% of range
This variant can also be used where there hysteresis ± 0.5% of range
are submerged solids in the process fluid.
Weight
It has a fluid filled chamber to transmit
the pressure in the process fluid to the 0.5 kg.
transducers sensor.
The pressure connection can be made to
suit the application.
TYPE 453 M High temperature version
This option is intended for use for high
temperatures it can also be used with high
temperatures and harsh fluids as it can be
fitted with corrosion resistant wetted parts.
This variant can be also be used where there
are submerged solids in the process fluid.
It has an oil fluid filled chamber to transmit
the pressure in the process fluid to the
transducers sensor.
High temperatures are cooled over the
copper tube which keeps the pressure
transducer at ambient temperature.
The pressure connection can be made to
suit the application.
Accuracy
linearity ± 1.0 % range
hysteresis ± 0.5% range
Temperature
Process temperature up to 200°C will not
give rise to additional errors
Weight
0.9 kg.
TYPE 453 N & 454 N Flange mounted version
This version is intended to be used where
pipe line flanges, hygienic fittings or
special custom connections are required.
Normally the connection is made from
stainless steel but other materials are
available.
The connection has a flush diaphragm
across the pressure opening.
Please note that it is the users responsibility
to ensure that the material specified is
compatible with the chemicals used and
It has an oil fluid filled chamber to transmit
the pressure in the process fluid to the
transducers sensor.
Accuracy
linearity ± 0.75 % of range
hysteresis ± 0.5% of range.
the application conditions of concentration
and temperature. For chemical compatibility
charts please see page 24 For further
Please note the
flange clamping
bolts must not
be slackened as
this will break the
pressure seal and
render the unit
inoperative.
Please note the
flange clamping
bolts must not
be slackened as
this will break the
pressure seal and
render the unit
inoperative.
Please note the
flange clamping
bolts must not
be slackened as
this will break the
pressure seal and
render the unit
inoperative.
information please contact our technical
department for the option and variants
shown above.
Series 4000 Pressure Transducers Series 4000 Pressure Transducers
This series of pressure transducers have
been designed where a simple low cost
device is required to give a readily usable
0–10V or 4-20 mA analogue signal. They
can be supplied for many applications
since the wetted parts can be selected
to meet a wide range of corrosive
requirements. CE marked models are fully
certified in accordance with EN 50081 &
EN 50082.
TYPE 4311
Ranges Ranges Ranges
250 mbar 25 mbar 10 mbar
400 mbar 50 mbar 20 mbar
1 bar 100 mbar
2 bar 160 mbar
4 bar
7 bar
10 bar
25 bar
1 bar vacuum
intermediate ranges available intermediate ranges available intermediate ranges available
Accuracy
Linearity & Hysteresis
combined ± 2% of range
FEATURES
5
Hall Effect (magnetic) Sensor
5
Ranges up to 25 bar
5
0 -10V dc or 4 - 20 mA output
5
Supplied with a Plug & socket
5
Pressure connection 1/2” bsp
parallel male
5
Weight 0.7 Kg
TYPE 4411
Materials of construction
Pressure Connection Brass
Diaphragm Beryllium Copper
Seal Nitrile rubber
Cover Anodised
Aluminium
TYPE 4511
See page 24 for alternative wetted parts
The units can be calibrated to intermediate
ranges but the accuracy will relate to
the appropriate diaphragm range shown
above.
Pressure Transducers Series 4000 Pressure Transducers Series 4000
General Specification
Calibration Temperature Effects Maintenance
Gain (span) and offset (zero) adjustment of
approx. ± 5% of range is provided under
cover.
Typically ±0.14% per °C between
15–30 °C. Calibrated at 20 °C.
Overpressure
All ranges will accept range plus 10%
No maintenance is required on these
transducers. On critical applications,
periodic checks of offset at zero pressure,
with slight adjustment, if necessary, will
maintain optimum performance.
TYPICAL WIRING DIAGRAMS
Voltage Output Current Output
Output load impedance
10k. min.
Output load impedance
250k. max.
SCREEN
PIN 1 OUTPUT
PIN 2 COMMON
PIN 3 SUPPLY (+VE)
PIN 4 NOT USED
SCREEN
PIN 1 OUTPUT
PIN 2 COMMON
PIN 3 SUPPLY (+VE)
PIN 4 NOT USED
LOAD
NOTE It is important that the connections are made correctly. Reverse voltage application will damage the transducer.
DIMENSIONS
Type 4311
Type 4411
Type
4511
CABLE GLAND TO SUIT
Ø 6.0 CABLE MAX
CABLE GLAND TO SUIT
Ø 6.0 CABLE MAX
CABLE GLAND TO SUIT
Ø 6.0 CABLE MAX
Ø 80.0
Ø 80.0 Ø 120.6
77.5 77.5
Ø 80.0
77.5
47.0
62.0
Ø 120.6
G 1/2 A
G 1/2 A
51.0
Ø 90.0
24.00 A
23.67 /F HEX
22.00 A
21.67 /F HEX
17.00 A
16.73 /F HEX
G 1/4 A
68.042.030.0
21.5
23.0
21.5
21.5
15.0
30.0
67.530.068.038.5
Part No. Suffixes Ordering Information – Example
CEA 4–20 mA output (CE marked). Type 4311 Pressure Transducer. Connection 1/2” bar.
CEB 0–10V dc Output (CE marked). Range 10 bar pressure. Fluid For use on water.
Series 4000 Differential Pressure Transducers Series 4000 Differential Pressure Transducers
This series of pressure transducers have
been designed as a simple low cost device
to monitor pressure difference between
a high and a low pressure. For example
across filters, through boilers etc. These
transducers can be used to measure flow
using orifice plates, pitot tubes etc (see
pages 21-23 for suitable digital displays
with square root output). CE marked
models are fully certified in accordance
with EN 50081 & EN 50082.
Features
5
Hall Effect (magnetic) Sensor
5
Differential pressure ranges up to
25 bar
5
0 -10V dc or 4 - 20 mA output
5
Supplied with a plug & socket
5
Weight 1.2 Kg
TYPE 4312
Ranges
250 mbar
400 mbar
1 bar
2 bar
4 bar
7 bar
10 bar
25 bar
1 bar vacuum
Max. line pressure 90 bar
intermediate ranges available
TYPE 4412
Ranges
25 mbar
50 mbar
100 mbar
160 mbar
Max. line pressure 34 bar
intermediate ranges available
TYPE 4512
Ranges
10 mbar
20 mbar
Max. line pressure 10 bar
intermediate ranges available
The units can be calibrated to intermediate ranges but the accuracy will relate to the appropriate sensor range shown above.
Accuracy Alternative wetted parts Ordering Information - Example
Linearity & Hysteresis Pressure Type 4412A Differential
combined ± 2% of range Connection 316 Stainless steel Pressure Transducer.
Materials of construction Diaphragm 17/7 ph Stainless steel Range 50 mbar differential
Seal according to fluid
pressure.
Pressure Line Pressure 20 bar.
Connection Brass Part No. Suffixes
Connection 1/8” bspp female.
Diaphragm Beryllium Copper
CEA 4 - 20 mA output Fluid For use on water.
Seal Nitrile rubber (CE marked).
Cover Anodised Aluminium CEB 0 - 10 V dc output
(CE marked).
Differential Pressure Transducers Series 4000 Differential Pressure Transducers Series 4000
General Specification
Calibration Temperature Effects Maintenance
Gain (span) and offset (zero) adjustment of
approx. ± 5% of range is provided under
cover.
Typically ±0.14% per °C between
15–30 °C. Calibrated at 20 °C.
Overpressure
All ranges will accept range plus 10%
No maintenance is required on these
transducers. On critical applications,
periodic checks of offset at zero pressure,
with slight adjustment, if necessary, will
maintain optimum performance.
TYPICAL WIRING DIAGRAMS
Output load impedance
10k. min.
Output load impedance
250k. max.
Voltage Output Current Output
PIN 1 OUTPUT
PIN 2 COMMON
PIN 3 SUPPLY (+VE)
PIN 4 NOT USED
PIN 1 OUTPUT
PIN 2 COMMON
PIN 3 SUPPLY (+VE)
PIN 4 NOT USED
LOAD
NOTE It is important that the connections are made correctly. Reverse voltage application will damage the transducer.
DIMENSIONS
Type
4312
Type
4412
Type
4512
CABLE GLAND TO SUIT
Ø 6.0 CABLE MAX
Ø 80.0
24.00 A
23.67 /F HEX CABLE GLAND TO SUIT
Ø 6.0 CABLE MAX
CABLE GLAND
Ø 6.0 CABLE
G 1/2 A G 1/8 G 1/8
Ø 80.0
Ø 80.0
77.5
77.5
77.5
47.0
51.0 62.0
Ø 90.0
Ø 120.8
68.042.0
91.030.0
91.030.0
21.5
21.521.5
30.08.0 16.2CRS
7.0 16.5CRS
Optional Addition to Features
Series 4000 Transducers
5
31/2 digit 10 mm high LCD display
All Hall Effect Pressure Transducers can be
fitted with a digital display in the lid. 5
4-20 mA or 0-10V dc output
5
Offset & Gain adjustment through
cover
5
Scaled in any pressure units
When ordering state Fitted with LCD
display’ after the pressure transducer
specification.
Type 4101 Pressure Transducers Type 4101 Pressure Transducers
This pressure transducer has been
specifically designed where high
electromagnetic radiation is present,
such as in fire appliances, hospitals, radio
transmitting stations etc.
It is totally immune to and does not radiate
any frequency of EMC.
Features
5
Suitable for use in EMC noisy
environments
5
0-10V dc output requires 12V dc
supply
5
3/8” bspp male connection
5
IP65 enclosure
5
Plug & socket electrical connection
WIRING DIAGRAM DIMENSIONS
PIN 1
OUTPUT BLUE
PIN 2
0V YELLOW
PIN 3
12V dc REGULATED RED
GROUND
GREEN/YELLOW
Pressure Ranges Accuracy Alternative wetted parts
Any pressure range from 0–25 bar
minimum to 0–700 bar maximum
Output
Linearity & Hysteresis
combined ± 2% of range
Materials of construction
Stainless steel
The transducers can be used on all fluids
compatable with the wetted parts.
Ratiometric Pressure
Connection Brass
Sensing
Element Phospher Bronze
Housing Anodised Aluminium
Pressure Transducers Type 73PT Pressure Transducers Type 73PT
Pressure gauge with high output signal.
Designed to give pressure indication and
electrical output signal for distant reading
in one unit and only one pressure tapping.
FEATURES
5
Gauge (g) ranges up to 600 bar g
5
Potentiometric or 4-20 mA output
5
6” dial pressure indication
5
Supplied with 1M flying lead
5
Weight 1.18kg
5
Pressure connection 1/2” BSP male
(alternatives available)
5
Bourdon tube sensing element
PART No. 73 PT for voltage output
PART No. 73 PTA for 4-20MA output
TYPE 73PT / 73PTA WIRING DIAGRAM
Gauge Pressures
For use with materials compatible
with brass and phosphor bronze
Ranges
-1/0 bar g 0/25 bar g
0/1 bar g 0/40 bar g
0/1.6 bar g 0/60 bar g
0/2.5 bar g 0/100 bar g
0/4 bar g 0/160 bar g
0/6 bar g 0/250 bar g
0/10 bar g 0/400 bar g
0/16 bar g 0/600 bar g
Alternative ranges available
73PTA Output: 4-20 mA
no signal.
73PT Ratiometric
73PTA 4-20 mA
73PT
Note: The coil will be damaged if full load is applied via the wiper.
Output: 0/2000 ohms (ranges up to 2.5 bar)
0/1570 ohms (ranges 4 bar and above)
minimum load impedance 4K ohms
Supply: 60V dc max regulated
max current 12mA
Accuracy
±1%
Output
2 Wire current loop
max load impedance
400 ohms
Supply: 12 to 24 V dc
Note: If the wiring is
reversed there will be
Type 70PT Pressure Transducers
Pressure gauge with high output signal for
harsh media.
Designed to give pressure indication and
electrical output signal for distant reading
in one unit and only one pressure tapping.
Features
5
Gauge (g) ranges up to 40 bar g
5
Potentiometric or 4-20 mA output
5
6” dial pressure indication
5
Supplied with 1M flying lead
5
Weight 1.2kg
5
Pressure connection 1/2” BSP male
(alternatives available)
5
Diaphragm sensing element
PART No. 70 PT for voltage output
PART No. 70 PTA for 4-20mA output
See page 24 for alternative wetted parts
TYPE 7OPT / 70PTA WIRING DIAGRAM
Gauge pressures
For use with materials compatible
with wetted parts specified.
Brass and BeCu - standard.
Seals - PTFE
Ranges
0/2.5 bar g
0/4 bar g
0/6 bar g
0/10 bar g
0/16 bar g
0/25 bar g
0/40 bar g
Alternative ranges available
Accuracy
± 1.5% f.s.
Output
73PT
Note:The coil will be damaged if full load is applied via the wiper.
Output: 0/2000 ohms
minimum load impedance 4K ohms
Supply: 60V dc
max current 12mA
73PTA
70PT Ratiometric
70PTA 4-20 mA
Output: 4-20 mA
2 Wire current loop
max load impedance
400 ohms
Supply: 12 to 24 V dc
Note:
If the wiring is
reversed there will be
no signal.
Pressure Transducers Type 69PT
73PT
Note:The coil will be damaged if full load is applied via the wiper.
Output: 0/2000 ohms
minimum load impedance 4K ohms
Supply: 60V dc
max current 12mA
Pressure gauge with high output signal.
Designed to give local indication of
pressure difference between two points
and electrical output signal for distant
reading in one unit.
Features
5
Differential ranges
5
Potentiometric or 4-20 mA output
5
6” dial pressure indication
5
Supplied with 1M flying lead
5
Weight 2kg
5
1/4” BSPFE connections
(alternatives available)
5
Diaphragm sensing element
5
Maximum line pressure 34 bar g
PART No. 69 PT for voltage output
PART No. 69 PTA for 4-20mA output
TYPE 69PT / 69PTA WIRING DIAGRAM
Differential pressures
For use with materials compatible
with brass, BeCu and nitrile.
Ranges
0/2.5 bar
0/4 bar
0/6 bar
Alternative ranges available
Maximum line pressure 34 bar
(not to be applied to one side only).
Accuracy
73PTA
± 2% f.s.
Output
69PT Ratiometric
69PTA 4-20 mA
Alternative wetted parts
Stainless steel and viton seals
Output: 4-20 mA
2 Wire current loop
max load impedance
400 ohms
Supply: 12 to 24 V dc
Note:
If the wiring is
reversed there will be
no signal.
Type 440 Analogue Displays Type 440 Analogue Displays
Low cost display for use with our range
of single ported and differential pressure
transducers and potentiometric pressure
gauges.
Features
5
96 Din case
5
Panel mounting
5
Rear screw terminals
5
0-10V & 4-20mA inputs
5
90° scale
5
IP54 enclosure
PART No. 440 A is for 4-20mA input
PART No. 440 B is for 0-10V dc
TYPE 440A&B
For use with 4-20mA or 0-10V output
transducers and potentiometric gauges
detailed in this catalogue.
Ranges
-1.0 bar vacuum up to
600 bar pressure.
Alternative scales available
Dimensions
Front face 96x96mm
Depth of case 43mm
Depth including terminals 60mm
Panel cutout 92x92mm
Accuracy
± 2% f.s.
Input
4-20 mA ñ 440A
0-10V ñ 440B
WIRING DIAGRAM
(provided with each unit)
440A
Separate power supply required 12 to 24V dc.
440B
Separate power supply required either 12 to 24V dc single rail
or 12-0-12 dual rail.
Digital Displays Type 441 Digital Displays Type 441
This display is intended for use with the
pressure transducers illustrated in this
catalogue. They can also be used in other
applications where digital indication of an
input value is required.
The displays are CE marked in accordance
with European legislation.
Features
5
14.2 mm high LEDs
5
1/8 din case
5
Factory set user configured
5
2 software alarms
5
90 - 265V ac or 12 - 24V dc input
option
5
Front panel conforms to IP 64
5
Square root extraction built-in
5
Powers all Bailey & Mackey
transducers directly
DIMENSIONS
Panel cut-out 93x45mm
Depth behind panel 175mm
Supplied with all connectors
Installation instructions provided with each display
General Specification
Calibration
Accessed from front panel
Alarms
Two software alarms
Power Supply
Input 90 to 265V ac or 12 to 24V dc
On mains units it is recommended that a
50 mA anti-surge fuse is fitted in the live
input supply to the display
Part No. Suffixes
A 4-20 mA
B 0-10V dc output
Ordering Information - Example
Type 441A
Supply 240V 50Hz
Calibration 0-10 bar
Type 442 Digital Displays Type 442 Digital Displays
Digital Display
Dual Alarm Type 442
This display is intended for use with the
pressure transducers illustrated in this
catalogue where two volt free alarm
contacts are required.
They can also be used in other applications
where digital indication of an input value
is required. The displays are CE marked in
accordance with European legislation.
Features
5
14.2 mm high LED’s
5
1/8 din case
5
Factory set user configured
5
2 spco volt free relay contacts
5
2 software alarms
5
90 - 265V ac or 12 - 24V dc input
option
5
Front panel conforms to IP 64
5
Square root extraction built in
5
Powers all Bailey & Mackey
transducers directly
DIMENSIONS
Panel cut-out 93x45mm
Depth behind panel 175mm
Supplied with all connectors
Installation instructions provided with each display
General Specification
Calibration
Accessed from front panel
Alarms
Two software alarms
Power Supply
Input 90 to 265V ac or 12 to 24V dc
On mains units it is recommended that a
50 mA anti-surge fuse is fitted in the live
input supply to the display
Part No. Suffixes
A 4-20 mA
B 0-10V dc output
Ordering Information - Example
Type 442A
Supply 240V 50Hz
Calibration 0-10 bar
Power Supplies Series 500 Power Supplies Series 500
The following power supplies have been selected for use with the
transducers illustrated in this catalogue.
Connection details are supplied with each power supply supplied.
To ensure the correct unit is used please contact our technical
department prior to ordering.
TYPE 553
For use with Type 453B & Type 454B
pressure transducers shown on page 4
Output: Dual rail adjustable
(10 to + 15V dc 0.5 A max.)
Supply: 240v 50/60 Hz only
Case: Enclosed type with
ventilation apertures
TYPE 555
For use with Type 045/3 and Type 045/4
shown on page 2
Output: Single rail fixed
(+5V dc 0.5 A max.)
Supply: 110/240V 50/60 Hz.
Case: Enclosed type with
ventilation apertures
TYPE 554
For use with Type 453, Type 454, Type 4311,
Type 4312, Type 4411, Type 4412, Type 4511 and 4512
pressure transducers shown on pages 4-16
Output: Single rail adjustable
(+10 to +20V dc 0.5A max.)
Supply: 240v 50/60Hz only
Case: Enclosed type with
ventilation apertures
TYPE 556
For use with Type 453, Type 454, Type 4311,
Type 4312, Type 4411, Type 4412 Type 4511 and 4512
pressure transducers shown on pages 4-16
Output: Single rail adjustable
(+12 to +15V dc 1.5 A max.)
Supply: 110/240V 50/60Hz only
Case: Open chassis type
Chemical Protection Pressure Transducers Chemical Protection Pressure Transducers
It is the user’s responsibility to ensure that the materials are compatible with the application.
Malleable Iron Base,
316 S.Steel Disc
Silver Plated Base,
Fine Silver Disc
UPVC Base 1/2” BSP,
PTFE Disc
316 Stainless Base
and Disc
Acetylene
Alkyl Chlorides
Ammonia (Max 60°C)
Aniline
Calcium Chloride (Max 60°C)
Caustic Soda (Max 60°C)
Chlorides of Na, K, Mg
Hydrocyanic Acid
Pyridine
Brines
Bromine
Chlorine (wet or dry)
chlorates of Na, K, Ba
Chlorides of Na, K, Mg
Flourine
Mercuric Chloride
Ozone
Max Temperature 40°C
Max Pressure 200 lbf/in2
Anhydrous Ammonia
Aluminium Chloride
Caustic Soda
Hydrobromic Acid (50%)
Hydrochloric Acid (36%)
Hydrogen Sulphide
Lead Acetate
Methanol
Oxalic Acid
Phosphoric Acid (50%)
Potassium Salts
Sodium Hypochlorite
Sodium Salts
Sulphuric Acid (70%)
Waste Gases
Acetic Acid
Ammonium Hydroxide
Carbon Disulphide
Carbon Tetrachloride
Caustic Soda
Caustic Potash
Citric Acid
Formic Acid
Fruit Juices
Food Machinery
Hexamine
Hydrogen Peroxide
Oil-Phosphate Ester Based
Silver Nitrate
Water De-ionised
Pressure Transducers Installation and Use Pressure Transducers Installation and Use
A Pressure Transducer correctly installed and to the correct
specification gives an electrical output proportional to the
pressure in the system which helps to ensure the safe working
of process plant and machinery.
a)
Before fitting the pressure transducer to a pressure source
check that the range (full scale) of the device is the same or
higher than the pressure to be applied.
b)
Before fitting the pressure transducer to a pressure source
check that the wetted parts are compatible with the fluid being
used, and that the pressure connection correctly matches that
of the pipework.
c)
When fitting the pressure transducer to pipework use correct
sealing methods. Do not use the transducer body to tighten
the pressure transducer to the pipework, use correct spanners
on the hexagon base.
d)
Do not use pressure transducers on Oxygen or Acetylene
unless approved by our Technical Department.
e)
Ambient and process temperature acting on the transducer
should be within catalogue values. The unit should be
protected from higher fluid temperatures by means of a
syphon tube filled with condensate before use. The fluid in
the pressure chamber should not be allowed to freeze or
crystallise as this will lead to rupture of the sensing element.
f)
Differential pressure transducers should not be used with
more than the range of the transducer applied to one side
unless approved by our Technical Department. Line pressure
must not exceed the line pressure stated on the pressure
transducers label. The higher of the two pressures must be
connected to the port marked high and the lower of the two
pressures must be connected to the port marked low.
g)
Ensure that the pressure transducer is connected electrically
in accordance with the installation instructions supplied
with the unit. Incorrect connection can damage the pressure
transducer beyond repair.
If in doubt concerning the application of any pressure transducer please contact
our Technical Department who will be only too pleased to give you advice.
Pressure Conversion Factors
Multiply units in left hand column by factor to obtain units at top. i.e. bar x 14.504 = lbf/in2
bar lbf/in2 kg/cm atm (std) MH2O inH20 mmHg inHg N/M2 Pa
bar 1 14.504 1.0197 0.9869 10.197 401.46 750.06 29.53 100000 100000 ‘
lbf/in2 0.0689 1 0.0703 0.068 0.7031 27.68 51.715 2.036 6894.8 6894.8
kg/cm2 0.9807 14.223 1 0.9678 10 393.7 735.56 28.959 98066 98066
atm (std) 1.0133 14.696 1.0332 1 10.332 406.78 760 29.921 101325 101325
MH2O 0.0981 1.4223 0.1 0.0968 1 39.37 73.556 2.8959 9806.6 9806.6
inH2O 0,0025 0.0361 0.0025 0.0025 0.0254 1 1.8683 0.0736 249.09 249.09
mmHg 0.0013 0.0193 0.0014 0.0013 0.0136 0.5352 1 0.0394 133.32 133.32
inHg 0.0339 0.4912 0.0345 0.0334 0.3453 13.595 25.4 1 3386.4 3386.4
N/M2 0.00001 0.00015 0.00001 0.00001 0.0001 0.004 0.0075 0.0003 1 1
Pa 0.00001 0.00015 0.00001 0.00001 0.0001 0.004 0.0075 0.0003 1 1
The right is reserved to change product specifications without prior notice.
OTHER PRODUCTS IN OUR RANGE
PRESSURE SWITCHES
DIAPHRAGM & DIFFERENTIAL
PRESSURE GAUGES
BOURDON TUBE
PRESSURE GAUGES
OTHER PRODUCTS IN OUR RANGE
PRESSURE SWITCHES
DIAPHRAGM & DIFFERENTIAL
PRESSURE GAUGES
BOURDON TUBE
PRESSURE GAUGES
Keeping pressure under control
This series of miniature pressure transducers
have a piezo-resistive sensor and a unique
conductive seal that eliminates internal wire
bonding thus enhancing reliability.
Zero and full scale adjusters are provided under
the top cover. They are ideal for use in areas
requiring exact pressure measurement. low
hysteresis and long term stability. For all
applications where air. oil or water is to be
monitored.
Pressure transducers are divided into two groups based on different measuring
technologies.
1 - Piezo-Resistive Transducers which use the voltage that is generated when a
semi-conductor beam is deflected by an applied pressure, this voltage is then
amplified which in turn gives a voltag or milli-amp output. These devices give
greater accuracies than the Hall Effect devices.
2 - Hall Effect Transducers use a magnet and a flux strength device to measure the
deflection of a diaphragm under pressure and give an analogue signal to an
amplifier which in turn gives a voltage or milli-amp output. These devices are
lower cost and have a similar accuracy to a pressure gauge.
Pressure Transducers
- 481 Piezo-Resistive Transducers
- 482 Piezo-Resistive d.p. Transducers
- 2200 & 2600 Piezo-Resistive Transducers
- 4000 Hall Effect Transducers
- 4000 Hall Effect d.p. Transducers
- 4101 Potentiometric Transducers
- 73PT Potentiometric Transducers
- Piezo-resistive sensor
- Ranges from full vacuum to 20 bar
- Type 481A for 12/24V d.c. input, 4-20mA output
- Type 481B for 24V a.c/d.c. input,
- 0-10V d.c. output
- Supplied with 1 M flying lead
- Pressure connection 1/4” bsp parallel male brass
- CE marked to EN 61000-6-2
- Complete with mounting bracket
- Enclosure rating IP65
- Weight 350 grams
The 2200 series features stability and accuracy in
a variety of enclosure options.
The 2600 series extends the packaging options
via an all welded stainless steel back end for
demanding submersible and industrial
applications.
The 2200 and the 2600 feature proven CVD
sensing technology, an ASIC (amplified units) and
modular packaging to provide a sensor line that
fits most applications and can easily
accommodate specials while not sacrificing high
performance.
- Gauge, absolutem vacuum and compound
pressure models available
- Submersible, general purpose and wash down
enclosures
- High stability achieved by CVD sensing element
- Millivolt, voltage and current output models
- Ranges from vacuum to 400 barG, 0 to 25 barA
- CE marked to EN 61000-6-2 and UL approved
- Pressure Ranges - Vacuum to 400 bar Gauge
and 0 to 25 bar Absolute
- Intermediate ranges to suit application.
- Proof Pressure 2 x FS (1.5 x FS for 400 barG)
This series of pressure transducers have been
designed as a simple low cost device to monitor
pressure difference between a high and a low
pressure.
For example across filters, through boilers etc.
These transducers can be used to measure flow
using orifice plates, pitot tubes etc.
CE marked models are fully certified in
accordance with EN 50081 & EN 50082.
- Hall Effect (magnetic) Sensor
- Differential pressure ranges up to 25 bar
- 0 -10V dc or 4 - 20 mA output
- Supplied with a plug & socket
- Weight 1.2 Kg
- Calibration - Gain (span) and offset (zero)
adjustment of approx. ± 5% of range.
- Temperature Effects: Typically ±0.14% per °C
between 15–30 °C. Calibrated at 20 °C.
- No maintenance required on these transducers.
On critical applications, periodic checks of
offset at zero pressure, with slight adjustment, if
necessary, will maintain optimum performance.
This pressure transducer has been specifically
designed where high electromagnetic radiation is
present, such as in fire appliances, hospitals,
radio transmitting stations etc.
It is totally immune to and does not radiate any
frequency of EMC.
- Suitable for use in EMC noisy environments
- 0-10V dc output requires 12V dc supply
- 3/8” bspp male connection
- IP65 enclosure
- Plug & socket electrical connection
- Any pressure range from 0–25 bar minimum to
0–700 bar maximum Output
- Stainless steel Construction





Neptech is proud to represent top quality Bailey & Mackey products in
North America. These products satisfy most pressure and temperature
sensing applications in many industrial markets including, Aerospace,
Automotive, Chemical, Marine, Medical, Water, Waste, Fire, Food,
Heating and Ventilating, and General Industries.
Expertise in pressure sensing technology enables us to manufacture
to the highest standard of quality and reliability. Our quality
management system, which is approved by B. S. I. Quality assurance
to BS EN 9001,ensures that all products have been correctly
assembled and tested prior to shipment.
Bailey & Mackey is a world leading manufacturer of Pressure Gauges,
Temperature Gauges, Pressure Switches and Pressure Transducers
as a result of excellence in customer service and product quality.
In fact, our pressure transducers require no maintenance. Periodic
calibration checks should be made and any re-calibration adjustments
made to ensure optimum performance.
Bailey & Mackey – Pressure control experience and innovation for
over 75 years
Instruments calibrated to correspond
with the pressure transducers.
- Potentiometric Transducers
- Voltage & current output devices
- Mono Pressures from 2.5 - 40 bar
- Potentiometric d.p.Transducers
- Voltage & current output devices
- Differential Pressures
- Displays & Power Supplies


Cabinets, Flexible Heaters, Canister Heaters, Chillers, CNG, Contact Us, Contract Manufacturing, Contract Services, Control Valves, Particulate Filters, Heated Lines, Filter Elements, Enclosures, Test Stands, Filter
Elements, Filter Housings, Fittings, Flow Control, Flow Switches, Gas Distribution Systems, Heat Exchangers, Heated Filters, Heated Products, Heated Blankets, Sample Probes, Connectors, Hot Melt, Hydraulic Fittings,
Home, Liquefied Natural Gas, Manufactured Products, Mechanical Enclosures, NEMA Enclosures, Capabilities, Manufacturing, Materials, On-Site Management, Systems Integration, Nitrogen Generators, Oxygen Generators,
Pipe Fittings, Pressure Control, Process, Product Line Card, Distributed Products, Replacement Filter Elements, Request Quote, Sub-Assembly, Technical Reference, Temperature Controllers, Thermocouples, Flexotherm